Company :
Address :
Telephone :
Contact :
Enquiry Date & Time:
Fax & E-mail :
Position :
New Application Existing Application
Type of equipment used in the past :
Problems with existing equipments ? :
Reason for Cleaning Gas ?
Air Pollution Control Recovery of Contaminations
Source of gas? :
Is there any pressure drop / draft other than the Scrubber ? Yes No
If yes, how much ? mm W.C.
Gas Volume SCFM (60° F, 30” Hg) ACFM Variance
Gas Pressure Gas Temperature Variance
Dry Gas Stream ? Yes No
If No,H2O VOLUME?
Gas Composition :
Compound :
Concentration :
Pollutants Physical nature ? Solid Liquid Gas
Corrosive? Yes No
Abrasive? Yes No
Toxic ? Yes No
Sticky? Yes No
Explosive ? Yes No
Fibrous ? Yes No
Hygroscopic ? Yes No
Spherical? Yes No
Solid Particulate or Mist Pollutants? Yes No
Concentration & type:
(If smoke is visible describe color, % opacity, trailing distance & photos if available)
Specific gravity ? : Lbs/ Cubic feet
bulk density : Lbs/ Cubic feet
Loading Concentration ?
Particle size (in micron)
% by weight
Above 40
20-40
10-20
5-10
1-5
Below 1
Characteristics ? Soluble in water Insoluble in water Corrosive Abrasive Sticking
What scrubbing liquid is preferred ? Water Alkali Acid
Is it desired to recirculate the scrubbing liquid? Yes No
Are process liquids available for scrubbing ? Yes No
Source of Liquid ? :
Liquid Temperature (available) ? :
Liquid Pressure (available)? :
Scrubber Efficiency required? :
Is it desired to cool the gas stream during scrubbing? Yes No
If so, to what final temperature? :
Preferred Materials of Construction? PP FRP Carbon Steel Stainless Steel If any others? (please specify) :
Design Pressure? :
Design Temperature? :
Location of Scrubber? :
What controls should the system have? :
What Scubber Accessories should be included in the System? :