BYPASS VALVE WITH ATOMIZING NOZZLE AT
THE OUTLET
At
the outlet of this valve the atomizing
nozzle is incorporated. The atomizing
steam is extracted from the high pressure
side of the valve shortly downstream the
valve seat. At the point of extraction
the pressure throttling is not yet initiated.
The atomizing steam is carried to the
nozzle via an external line. No additional
steam valve is required.
ADVANTAGES :
Excellent spray water evaporation using
high mechanical energy of atomizing steam
Excellent temperature control as close
as 3 - 4 deg. C. above saturation.team.
Short straight outlet line required
even at low steam velocities.
High turndown ratio of 30:1.
Ideal for large amount of spray water.
Separate steam atomizing valve not required.
* On Request